HOW TO SIZE YOUR SYSTEM – WE RECOMMEND YOU ALWAYS SPEAK WITH AN ELECTRICIAN, HOWEVER, AN EASY WAY TO GET AN ESTIMATED SIZE IS USE THE CALCULATOR BELOW OR LOOK AT YOUR MONTHLY POWER BILL ON YOUR MOST EXPENSIVE MONTH. FROM THERE, DECIDE HOW MANY DAYS/WEEKS OF BACKUP POWER YOU WANT IN CASE OF EMERGENCIES AND DO THE MATH. CONSUMPTION VARIES GREATLY IF YOU’RE LOOKING TO RUN YOUR ENTIRE HOUSE OR ONLY A FEW EMERGENCY CIRCUITS. PLEASE SPEAK WITH A LOCAL ELECTRICIAN OR INQUIRE WITH US AFTER PURCHASE ASSIST YOU IN LOCATING A QUALIFIED INSTALLER. PLEASE REMEMBER IF YOU HAVE TANKLESS WATER HEATER, WITHOUT SOME FORM OF BACK-UP, YOU WILL LOSE HOT WATER IN THE EVENT OF A POWER OUTAGE.
Sizing is measured in kwh
Daily Usage: 29.96
Estimated Energy Storage Needed: 0.00
FETHS-48051 G-1 CNT&060
• CANBus/RS485 communications
• IP65 protection rating
• Interactive LED Display
• Up to (16) units per control box (81.6 kWh)
• Smart BMS with auto-cell balancing
• Bluetooth monitoring
• UL9540, UL9540a, & UL1973 certified
• UN38.3 & CE certified
Note: BulkAbsorption, Float, and Equalize are not applicable to lithium batteries but are included here with the correct numbers to input into your charge controller as they
are our most commonly requested parameters.
System Voltage | 48V |
Charge Voltage | 57V |
Bulk Voltage | 57V |
Absorption Voltage | 57V |
Absorption Time | 0 minutes |
Float Voltage | 55V |
Equalize | Off |
Low Voltage Cutoff | 48V |
High Voltage Cutoff | 57V |
Suggested Inverter Low Voltage Setting | 50.8V |
Nominal Voltage | 51.2V |
Chemistry | LiFeP04 |
kwh Capacity | 10.24 kwh |
Ah Capacity | 200 Ah |
Charging Voltage Range | 55.6V - 57V |
Max Charge Voltage | 57V |
Operating Voltage Range | 48V - 57V |
Suggested Low Voltage Cutoff | 48V - 50.8V |
BMS cutoff Range | 42V - 47V |
Cell Configuration | 16S 2P |
Max continuous Discharge Current | 10240W |
Max Continuous Power | 50.8V |
Max Discharge Peak Current | 300A (Max 5 seconds) |
Max Charge Current | 200A |
Charge Temperature Range | 32°F - 113°F (0°C - 45°C) |
Discharge Temperature Range | -4°F - 140°F (-20°C - 60°C) |
Optical Discharge Temperature Range | 59°F - 95°F (15°C - 35°C) |
Stroage Temperature Range (SoC > 50%) | -4°F - 113°F (20°C - 45°C)(Max 6 months) |
These batteries use a standard M8 terminal. Each module can be connected using the include ring terminal cables.
These batteries are not series capable but can be connected in parallel up to 16 times. Make sure that the total amount of these batteries in your configuration never exceeds sixteen total batteries. When connecting batteries in parallel, ensure all batteries are within 1 volt of another.
Lithium iron phosphate (LiFe-P04) batteries can be cycled from 3500 - 5000 times. If you can get more than 10 years of use from your battery. WHen your battery is at the end of its lifespan, contact us and we'll re-cycle it for you!
Please use the contact form and bank transfer information will be sent over with an invoice for payment.